Exemplo n.º 1
0
Arquivo: asm.go Projeto: SpiderOak/go
func adddynrel(ctxt *ld.Link, s *ld.Symbol, r *ld.Reloc) {
	targ := r.Sym
	ctxt.Cursym = s

	switch r.Type {
	default:
		if r.Type >= 256 {
			ctxt.Diag("unexpected relocation type %d", r.Type)
			return
		}

		// Handle relocations found in ELF object files.
	case 256 + ld.R_X86_64_PC32:
		if targ.Type == obj.SDYNIMPORT {
			ctxt.Diag("unexpected R_X86_64_PC32 relocation for dynamic symbol %s", targ.Name)
		}
		if targ.Type == 0 || targ.Type == obj.SXREF {
			ctxt.Diag("unknown symbol %s in pcrel", targ.Name)
		}
		r.Type = obj.R_PCREL
		r.Add += 4
		return

	case 256 + ld.R_X86_64_PLT32:
		r.Type = obj.R_PCREL
		r.Add += 4
		if targ.Type == obj.SDYNIMPORT {
			addpltsym(ctxt, targ)
			r.Sym = ld.Linklookup(ctxt, ".plt", 0)
			r.Add += int64(targ.Plt)
		}

		return

	case 256 + ld.R_X86_64_GOTPCREL, 256 + ld.R_X86_64_GOTPCRELX, 256 + ld.R_X86_64_REX_GOTPCRELX:
		if targ.Type != obj.SDYNIMPORT {
			// have symbol
			if r.Off >= 2 && s.P[r.Off-2] == 0x8b {
				// turn MOVQ of GOT entry into LEAQ of symbol itself
				s.P[r.Off-2] = 0x8d

				r.Type = obj.R_PCREL
				r.Add += 4
				return
			}
		}

		// fall back to using GOT and hope for the best (CMOV*)
		// TODO: just needs relocation, no need to put in .dynsym
		addgotsym(ctxt, targ)

		r.Type = obj.R_PCREL
		r.Sym = ld.Linklookup(ctxt, ".got", 0)
		r.Add += 4
		r.Add += int64(targ.Got)
		return

	case 256 + ld.R_X86_64_64:
		if targ.Type == obj.SDYNIMPORT {
			ctxt.Diag("unexpected R_X86_64_64 relocation for dynamic symbol %s", targ.Name)
		}
		r.Type = obj.R_ADDR
		return

	// Handle relocations found in Mach-O object files.
	case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 0,
		512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 0,
		512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 0:
		// TODO: What is the difference between all these?
		r.Type = obj.R_ADDR

		if targ.Type == obj.SDYNIMPORT {
			ctxt.Diag("unexpected reloc for dynamic symbol %s", targ.Name)
		}
		return

	case 512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 1:
		if targ.Type == obj.SDYNIMPORT {
			addpltsym(ctxt, targ)
			r.Sym = ld.Linklookup(ctxt, ".plt", 0)
			r.Add = int64(targ.Plt)
			r.Type = obj.R_PCREL
			return
		}
		fallthrough

		// fall through
	case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED_1*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED_2*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED_4*2 + 1:
		r.Type = obj.R_PCREL

		if targ.Type == obj.SDYNIMPORT {
			ctxt.Diag("unexpected pc-relative reloc for dynamic symbol %s", targ.Name)
		}
		return

	case 512 + ld.MACHO_X86_64_RELOC_GOT_LOAD*2 + 1:
		if targ.Type != obj.SDYNIMPORT {
			// have symbol
			// turn MOVQ of GOT entry into LEAQ of symbol itself
			if r.Off < 2 || s.P[r.Off-2] != 0x8b {
				ctxt.Diag("unexpected GOT_LOAD reloc for non-dynamic symbol %s", targ.Name)
				return
			}

			s.P[r.Off-2] = 0x8d
			r.Type = obj.R_PCREL
			return
		}
		fallthrough

		// fall through
	case 512 + ld.MACHO_X86_64_RELOC_GOT*2 + 1:
		if targ.Type != obj.SDYNIMPORT {
			ctxt.Diag("unexpected GOT reloc for non-dynamic symbol %s", targ.Name)
		}
		addgotsym(ctxt, targ)
		r.Type = obj.R_PCREL
		r.Sym = ld.Linklookup(ctxt, ".got", 0)
		r.Add += int64(targ.Got)
		return
	}

	// Handle references to ELF symbols from our own object files.
	if targ.Type != obj.SDYNIMPORT {
		return
	}

	switch r.Type {
	case obj.R_CALL,
		obj.R_PCREL:
		if ld.HEADTYPE == obj.Hwindows {
			// nothing to do, the relocation will be laid out in pereloc1
			return
		} else {
			// for both ELF and Mach-O
			addpltsym(ctxt, targ)
			r.Sym = ld.Linklookup(ctxt, ".plt", 0)
			r.Add = int64(targ.Plt)
			return
		}

	case obj.R_ADDR:
		if s.Type == obj.STEXT && ld.Iself {
			if ld.HEADTYPE == obj.Hsolaris {
				addpltsym(ctxt, targ)
				r.Sym = ld.Linklookup(ctxt, ".plt", 0)
				r.Add += int64(targ.Plt)
				return
			}
			// The code is asking for the address of an external
			// function. We provide it with the address of the
			// correspondent GOT symbol.
			addgotsym(ctxt, targ)

			r.Sym = ld.Linklookup(ctxt, ".got", 0)
			r.Add += int64(targ.Got)
			return
		}

		if s.Type != obj.SDATA {
			break
		}
		if ld.Iself {
			ld.Adddynsym(ctxt, targ)
			rela := ld.Linklookup(ctxt, ".rela", 0)
			ld.Addaddrplus(ctxt, rela, s, int64(r.Off))
			if r.Siz == 8 {
				ld.Adduint64(ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_X86_64_64))
			} else {
				ld.Adduint64(ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_X86_64_32))
			}
			ld.Adduint64(ctxt, rela, uint64(r.Add))
			r.Type = 256 // ignore during relocsym
			return
		}

		if ld.HEADTYPE == obj.Hdarwin && s.Size == int64(ld.SysArch.PtrSize) && r.Off == 0 {
			// Mach-O relocations are a royal pain to lay out.
			// They use a compact stateful bytecode representation
			// that is too much bother to deal with.
			// Instead, interpret the C declaration
			//	void *_Cvar_stderr = &stderr;
			// as making _Cvar_stderr the name of a GOT entry
			// for stderr. This is separate from the usual GOT entry,
			// just in case the C code assigns to the variable,
			// and of course it only works for single pointers,
			// but we only need to support cgo and that's all it needs.
			ld.Adddynsym(ctxt, targ)

			got := ld.Linklookup(ctxt, ".got", 0)
			s.Type = got.Type | obj.SSUB
			s.Outer = got
			s.Sub = got.Sub
			got.Sub = s
			s.Value = got.Size
			ld.Adduint64(ctxt, got, 0)
			ld.Adduint32(ctxt, ld.Linklookup(ctxt, ".linkedit.got", 0), uint32(targ.Dynid))
			r.Type = 256 // ignore during relocsym
			return
		}

		if ld.HEADTYPE == obj.Hwindows {
			// nothing to do, the relocation will be laid out in pereloc1
			return
		}
	}

	ctxt.Cursym = s
	ctxt.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type)
}
Exemplo n.º 2
0
Arquivo: asm.go Projeto: SpiderOak/go
func adddynrel(ctxt *ld.Link, s *ld.Symbol, r *ld.Reloc) {
	targ := r.Sym
	ctxt.Cursym = s

	switch r.Type {
	default:
		if r.Type >= 256 {
			ctxt.Diag("unexpected relocation type %d", r.Type)
			return
		}

		// Handle relocations found in ELF object files.
	case 256 + ld.R_386_PC32:
		if targ.Type == obj.SDYNIMPORT {
			ctxt.Diag("unexpected R_386_PC32 relocation for dynamic symbol %s", targ.Name)
		}
		if targ.Type == 0 || targ.Type == obj.SXREF {
			ctxt.Diag("unknown symbol %s in pcrel", targ.Name)
		}
		r.Type = obj.R_PCREL
		r.Add += 4
		return

	case 256 + ld.R_386_PLT32:
		r.Type = obj.R_PCREL
		r.Add += 4
		if targ.Type == obj.SDYNIMPORT {
			addpltsym(ctxt, targ)
			r.Sym = ld.Linklookup(ctxt, ".plt", 0)
			r.Add += int64(targ.Plt)
		}

		return

	case 256 + ld.R_386_GOT32, 256 + ld.R_386_GOT32X:
		if targ.Type != obj.SDYNIMPORT {
			// have symbol
			if r.Off >= 2 && s.P[r.Off-2] == 0x8b {
				// turn MOVL of GOT entry into LEAL of symbol address, relative to GOT.
				s.P[r.Off-2] = 0x8d

				r.Type = obj.R_GOTOFF
				return
			}

			if r.Off >= 2 && s.P[r.Off-2] == 0xff && s.P[r.Off-1] == 0xb3 {
				// turn PUSHL of GOT entry into PUSHL of symbol itself.
				// use unnecessary SS prefix to keep instruction same length.
				s.P[r.Off-2] = 0x36

				s.P[r.Off-1] = 0x68
				r.Type = obj.R_ADDR
				return
			}

			ctxt.Diag("unexpected GOT reloc for non-dynamic symbol %s", targ.Name)
			return
		}

		addgotsym(ctxt, targ)
		r.Type = obj.R_CONST // write r->add during relocsym
		r.Sym = nil
		r.Add += int64(targ.Got)
		return

	case 256 + ld.R_386_GOTOFF:
		r.Type = obj.R_GOTOFF
		return

	case 256 + ld.R_386_GOTPC:
		r.Type = obj.R_PCREL
		r.Sym = ld.Linklookup(ctxt, ".got", 0)
		r.Add += 4
		return

	case 256 + ld.R_386_32:
		if targ.Type == obj.SDYNIMPORT {
			ctxt.Diag("unexpected R_386_32 relocation for dynamic symbol %s", targ.Name)
		}
		r.Type = obj.R_ADDR
		return

	case 512 + ld.MACHO_GENERIC_RELOC_VANILLA*2 + 0:
		r.Type = obj.R_ADDR
		if targ.Type == obj.SDYNIMPORT {
			ctxt.Diag("unexpected reloc for dynamic symbol %s", targ.Name)
		}
		return

	case 512 + ld.MACHO_GENERIC_RELOC_VANILLA*2 + 1:
		if targ.Type == obj.SDYNIMPORT {
			addpltsym(ctxt, targ)
			r.Sym = ld.Linklookup(ctxt, ".plt", 0)
			r.Add = int64(targ.Plt)
			r.Type = obj.R_PCREL
			return
		}

		r.Type = obj.R_PCREL
		return

	case 512 + ld.MACHO_FAKE_GOTPCREL:
		if targ.Type != obj.SDYNIMPORT {
			// have symbol
			// turn MOVL of GOT entry into LEAL of symbol itself
			if r.Off < 2 || s.P[r.Off-2] != 0x8b {
				ctxt.Diag("unexpected GOT reloc for non-dynamic symbol %s", targ.Name)
				return
			}

			s.P[r.Off-2] = 0x8d
			r.Type = obj.R_PCREL
			return
		}

		addgotsym(ctxt, targ)
		r.Sym = ld.Linklookup(ctxt, ".got", 0)
		r.Add += int64(targ.Got)
		r.Type = obj.R_PCREL
		return
	}

	// Handle references to ELF symbols from our own object files.
	if targ.Type != obj.SDYNIMPORT {
		return
	}

	switch r.Type {
	case obj.R_CALL,
		obj.R_PCREL:
		addpltsym(ctxt, targ)
		r.Sym = ld.Linklookup(ctxt, ".plt", 0)
		r.Add = int64(targ.Plt)
		return

	case obj.R_ADDR:
		if s.Type != obj.SDATA {
			break
		}
		if ld.Iself {
			ld.Adddynsym(ctxt, targ)
			rel := ld.Linklookup(ctxt, ".rel", 0)
			ld.Addaddrplus(ctxt, rel, s, int64(r.Off))
			ld.Adduint32(ctxt, rel, ld.ELF32_R_INFO(uint32(targ.Dynid), ld.R_386_32))
			r.Type = obj.R_CONST // write r->add during relocsym
			r.Sym = nil
			return
		}

		if ld.HEADTYPE == obj.Hdarwin && s.Size == int64(ld.SysArch.PtrSize) && r.Off == 0 {
			// Mach-O relocations are a royal pain to lay out.
			// They use a compact stateful bytecode representation
			// that is too much bother to deal with.
			// Instead, interpret the C declaration
			//	void *_Cvar_stderr = &stderr;
			// as making _Cvar_stderr the name of a GOT entry
			// for stderr. This is separate from the usual GOT entry,
			// just in case the C code assigns to the variable,
			// and of course it only works for single pointers,
			// but we only need to support cgo and that's all it needs.
			ld.Adddynsym(ctxt, targ)

			got := ld.Linklookup(ctxt, ".got", 0)
			s.Type = got.Type | obj.SSUB
			s.Outer = got
			s.Sub = got.Sub
			got.Sub = s
			s.Value = got.Size
			ld.Adduint32(ctxt, got, 0)
			ld.Adduint32(ctxt, ld.Linklookup(ctxt, ".linkedit.got", 0), uint32(targ.Dynid))
			r.Type = 256 // ignore during relocsym
			return
		}

		if ld.HEADTYPE == obj.Hwindows && s.Size == int64(ld.SysArch.PtrSize) {
			// nothing to do, the relocation will be laid out in pereloc1
			return
		}
	}

	ctxt.Cursym = s
	ctxt.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type)
}
Exemplo n.º 3
0
Arquivo: asm.go Projeto: achanda/go
func adddynrel(ctxt *ld.Link, s *ld.Symbol, r *ld.Reloc) bool {
	targ := r.Sym

	switch r.Type {
	default:
		if r.Type >= 256 {
			ld.Errorf(s, "unexpected relocation type %d", r.Type)
			return false
		}

		// Handle relocations found in ELF object files.
	case 256 + ld.R_X86_64_PC32:
		if targ.Type == obj.SDYNIMPORT {
			ld.Errorf(s, "unexpected R_X86_64_PC32 relocation for dynamic symbol %s", targ.Name)
		}
		if targ.Type == 0 || targ.Type == obj.SXREF {
			ld.Errorf(s, "unknown symbol %s in pcrel", targ.Name)
		}
		r.Type = obj.R_PCREL
		r.Add += 4
		return true

	case 256 + ld.R_X86_64_PLT32:
		r.Type = obj.R_PCREL
		r.Add += 4
		if targ.Type == obj.SDYNIMPORT {
			addpltsym(ctxt, targ)
			r.Sym = ctxt.Syms.Lookup(".plt", 0)
			r.Add += int64(targ.Plt)
		}

		return true

	case 256 + ld.R_X86_64_GOTPCREL, 256 + ld.R_X86_64_GOTPCRELX, 256 + ld.R_X86_64_REX_GOTPCRELX:
		if targ.Type != obj.SDYNIMPORT {
			// have symbol
			if r.Off >= 2 && s.P[r.Off-2] == 0x8b {
				// turn MOVQ of GOT entry into LEAQ of symbol itself
				s.P[r.Off-2] = 0x8d

				r.Type = obj.R_PCREL
				r.Add += 4
				return true
			}
		}

		// fall back to using GOT and hope for the best (CMOV*)
		// TODO: just needs relocation, no need to put in .dynsym
		addgotsym(ctxt, targ)

		r.Type = obj.R_PCREL
		r.Sym = ctxt.Syms.Lookup(".got", 0)
		r.Add += 4
		r.Add += int64(targ.Got)
		return true

	case 256 + ld.R_X86_64_64:
		if targ.Type == obj.SDYNIMPORT {
			ld.Errorf(s, "unexpected R_X86_64_64 relocation for dynamic symbol %s", targ.Name)
		}
		r.Type = obj.R_ADDR
		return true

	// Handle relocations found in Mach-O object files.
	case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 0,
		512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 0,
		512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 0:
		// TODO: What is the difference between all these?
		r.Type = obj.R_ADDR

		if targ.Type == obj.SDYNIMPORT {
			ld.Errorf(s, "unexpected reloc for dynamic symbol %s", targ.Name)
		}
		return true

	case 512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 1:
		if targ.Type == obj.SDYNIMPORT {
			addpltsym(ctxt, targ)
			r.Sym = ctxt.Syms.Lookup(".plt", 0)
			r.Add = int64(targ.Plt)
			r.Type = obj.R_PCREL
			return true
		}
		fallthrough

		// fall through
	case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED_1*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED_2*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED_4*2 + 1:
		r.Type = obj.R_PCREL

		if targ.Type == obj.SDYNIMPORT {
			ld.Errorf(s, "unexpected pc-relative reloc for dynamic symbol %s", targ.Name)
		}
		return true

	case 512 + ld.MACHO_X86_64_RELOC_GOT_LOAD*2 + 1:
		if targ.Type != obj.SDYNIMPORT {
			// have symbol
			// turn MOVQ of GOT entry into LEAQ of symbol itself
			if r.Off < 2 || s.P[r.Off-2] != 0x8b {
				ld.Errorf(s, "unexpected GOT_LOAD reloc for non-dynamic symbol %s", targ.Name)
				return false
			}

			s.P[r.Off-2] = 0x8d
			r.Type = obj.R_PCREL
			return true
		}
		fallthrough

		// fall through
	case 512 + ld.MACHO_X86_64_RELOC_GOT*2 + 1:
		if targ.Type != obj.SDYNIMPORT {
			ld.Errorf(s, "unexpected GOT reloc for non-dynamic symbol %s", targ.Name)
		}
		addgotsym(ctxt, targ)
		r.Type = obj.R_PCREL
		r.Sym = ctxt.Syms.Lookup(".got", 0)
		r.Add += int64(targ.Got)
		return true
	}

	switch r.Type {
	case obj.R_CALL,
		obj.R_PCREL:
		if targ.Type != obj.SDYNIMPORT {
			// nothing to do, the relocation will be laid out in reloc
			return true
		}
		if ld.Headtype == obj.Hwindows || ld.Headtype == obj.Hwindowsgui {
			// nothing to do, the relocation will be laid out in pereloc1
			return true
		} else {
			// for both ELF and Mach-O
			addpltsym(ctxt, targ)
			r.Sym = ctxt.Syms.Lookup(".plt", 0)
			r.Add = int64(targ.Plt)
			return true
		}

	case obj.R_ADDR:
		if s.Type == obj.STEXT && ld.Iself {
			if ld.Headtype == obj.Hsolaris {
				addpltsym(ctxt, targ)
				r.Sym = ctxt.Syms.Lookup(".plt", 0)
				r.Add += int64(targ.Plt)
				return true
			}
			// The code is asking for the address of an external
			// function. We provide it with the address of the
			// correspondent GOT symbol.
			addgotsym(ctxt, targ)

			r.Sym = ctxt.Syms.Lookup(".got", 0)
			r.Add += int64(targ.Got)
			return true
		}

		// Process dynamic relocations for the data sections.
		if ld.Buildmode == ld.BuildmodePIE && ld.Linkmode == ld.LinkInternal {
			// When internally linking, generate dynamic relocations
			// for all typical R_ADDR relocations. The exception
			// are those R_ADDR that are created as part of generating
			// the dynamic relocations and must be resolved statically.
			//
			// There are three phases relevant to understanding this:
			//
			//	dodata()  // we are here
			//	address() // symbol address assignment
			//	reloc()   // resolution of static R_ADDR relocs
			//
			// At this point symbol addresses have not been
			// assigned yet (as the final size of the .rela section
			// will affect the addresses), and so we cannot write
			// the Elf64_Rela.r_offset now. Instead we delay it
			// until after the 'address' phase of the linker is
			// complete. We do this via Addaddrplus, which creates
			// a new R_ADDR relocation which will be resolved in
			// the 'reloc' phase.
			//
			// These synthetic static R_ADDR relocs must be skipped
			// now, or else we will be caught in an infinite loop
			// of generating synthetic relocs for our synthetic
			// relocs.
			switch s.Name {
			case ".dynsym", ".rela", ".got.plt", ".dynamic":
				return false
			}
		} else {
			// Either internally linking a static executable,
			// in which case we can resolve these relocations
			// statically in the 'reloc' phase, or externally
			// linking, in which case the relocation will be
			// prepared in the 'reloc' phase and passed to the
			// external linker in the 'asmb' phase.
			if s.Type != obj.SDATA && s.Type != obj.SRODATA {
				break
			}
		}

		if ld.Iself {
			// TODO: We generate a R_X86_64_64 relocation for every R_ADDR, even
			// though it would be more efficient (for the dynamic linker) if we
			// generated R_X86_RELATIVE instead.
			ld.Adddynsym(ctxt, targ)
			rela := ctxt.Syms.Lookup(".rela", 0)
			ld.Addaddrplus(ctxt, rela, s, int64(r.Off))
			if r.Siz == 8 {
				ld.Adduint64(ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_X86_64_64))
			} else {
				// TODO: never happens, remove.
				ld.Adduint64(ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_X86_64_32))
			}
			ld.Adduint64(ctxt, rela, uint64(r.Add))
			r.Type = 256 // ignore during relocsym
			return true
		}

		if ld.Headtype == obj.Hdarwin && s.Size == int64(ld.SysArch.PtrSize) && r.Off == 0 {
			// Mach-O relocations are a royal pain to lay out.
			// They use a compact stateful bytecode representation
			// that is too much bother to deal with.
			// Instead, interpret the C declaration
			//	void *_Cvar_stderr = &stderr;
			// as making _Cvar_stderr the name of a GOT entry
			// for stderr. This is separate from the usual GOT entry,
			// just in case the C code assigns to the variable,
			// and of course it only works for single pointers,
			// but we only need to support cgo and that's all it needs.
			ld.Adddynsym(ctxt, targ)

			got := ctxt.Syms.Lookup(".got", 0)
			s.Type = got.Type | obj.SSUB
			s.Outer = got
			s.Sub = got.Sub
			got.Sub = s
			s.Value = got.Size
			ld.Adduint64(ctxt, got, 0)
			ld.Adduint32(ctxt, ctxt.Syms.Lookup(".linkedit.got", 0), uint32(targ.Dynid))
			r.Type = 256 // ignore during relocsym
			return true
		}

		if ld.Headtype == obj.Hwindows || ld.Headtype == obj.Hwindowsgui {
			// nothing to do, the relocation will be laid out in pereloc1
			return true
		}
	}

	return false
}