Beispiel #1
0
func adddynrel(s *ld.LSym, r *ld.Reloc) {
	targ := r.Sym
	ld.Ctxt.Cursym = s

	switch r.Type {
	default:
		if r.Type >= 256 {
			ld.Diag("unexpected relocation type %d", r.Type)
			return
		}

		// Handle relocations found in ELF object files.
	case 256 + ld.R_ARM_PLT32:
		r.Type = ld.R_CALLARM

		if targ.Type == ld.SDYNIMPORT {
			addpltsym(ld.Ctxt, targ)
			r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
			r.Add = int64(braddoff(int32(r.Add), targ.Plt/4))
		}

		return

	case 256 + ld.R_ARM_THM_PC22: // R_ARM_THM_CALL
		ld.Diag("R_ARM_THM_CALL, are you using -marm?")

		ld.Errorexit()
		return

	case 256 + ld.R_ARM_GOT32: // R_ARM_GOT_BREL
		if targ.Type != ld.SDYNIMPORT {
			addgotsyminternal(ld.Ctxt, targ)
		} else {
			addgotsym(ld.Ctxt, targ)
		}

		r.Type = ld.R_CONST // write r->add during relocsym
		r.Sym = nil
		r.Add += int64(targ.Got)
		return

	case 256 + ld.R_ARM_GOT_PREL: // GOT(nil) + A - nil
		if targ.Type != ld.SDYNIMPORT {
			addgotsyminternal(ld.Ctxt, targ)
		} else {
			addgotsym(ld.Ctxt, targ)
		}

		r.Type = ld.R_PCREL
		r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0)
		r.Add += int64(targ.Got) + 4
		return

	case 256 + ld.R_ARM_GOTOFF: // R_ARM_GOTOFF32
		r.Type = ld.R_GOTOFF

		return

	case 256 + ld.R_ARM_GOTPC: // R_ARM_BASE_PREL
		r.Type = ld.R_PCREL

		r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0)
		r.Add += 4
		return

	case 256 + ld.R_ARM_CALL:
		r.Type = ld.R_CALLARM
		if targ.Type == ld.SDYNIMPORT {
			addpltsym(ld.Ctxt, targ)
			r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
			r.Add = int64(braddoff(int32(r.Add), targ.Plt/4))
		}

		return

	case 256 + ld.R_ARM_REL32: // R_ARM_REL32
		r.Type = ld.R_PCREL

		r.Add += 4
		return

	case 256 + ld.R_ARM_ABS32:
		if targ.Type == ld.SDYNIMPORT {
			ld.Diag("unexpected R_ARM_ABS32 relocation for dynamic symbol %s", targ.Name)
		}
		r.Type = ld.R_ADDR
		return

		// we can just ignore this, because we are targeting ARM V5+ anyway
	case 256 + ld.R_ARM_V4BX:
		if r.Sym != nil {
			// R_ARM_V4BX is ABS relocation, so this symbol is a dummy symbol, ignore it
			r.Sym.Type = 0
		}

		r.Sym = nil
		return

	case 256 + ld.R_ARM_PC24,
		256 + ld.R_ARM_JUMP24:
		r.Type = ld.R_CALLARM
		if targ.Type == ld.SDYNIMPORT {
			addpltsym(ld.Ctxt, targ)
			r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
			r.Add = int64(braddoff(int32(r.Add), targ.Plt/4))
		}

		return
	}

	// Handle references to ELF symbols from our own object files.
	if targ.Type != ld.SDYNIMPORT {
		return
	}

	switch r.Type {
	case ld.R_CALLARM:
		addpltsym(ld.Ctxt, targ)
		r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
		r.Add = int64(targ.Plt)
		return

	case ld.R_ADDR:
		if s.Type != ld.SDATA {
			break
		}
		if ld.Iself {
			adddynsym(ld.Ctxt, targ)
			rel := ld.Linklookup(ld.Ctxt, ".rel", 0)
			ld.Addaddrplus(ld.Ctxt, rel, s, int64(r.Off))
			ld.Adduint32(ld.Ctxt, rel, ld.ELF32_R_INFO(uint32(targ.Dynid), ld.R_ARM_GLOB_DAT)) // we need a nil + A dynmic reloc
			r.Type = ld.R_CONST                                                                // write r->add during relocsym
			r.Sym = nil
			return
		}
	}

	ld.Ctxt.Cursym = s
	ld.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type)
}
Beispiel #2
0
func adddynrel(s *ld.LSym, r *ld.Reloc) {
	targ := r.Sym
	ld.Ctxt.Cursym = s

	switch r.Type {
	default:
		if r.Type >= 256 {
			ld.Diag("unexpected relocation type %d", r.Type)
			return
		}

		// Handle relocations found in ELF object files.
	case 256 + ld.R_X86_64_PC32:
		if targ.Type == ld.SDYNIMPORT {
			ld.Diag("unexpected R_X86_64_PC32 relocation for dynamic symbol %s", targ.Name)
		}
		if targ.Type == 0 || targ.Type == ld.SXREF {
			ld.Diag("unknown symbol %s in pcrel", targ.Name)
		}
		r.Type = ld.R_PCREL
		r.Add += 4
		return

	case 256 + ld.R_X86_64_PLT32:
		r.Type = ld.R_PCREL
		r.Add += 4
		if targ.Type == ld.SDYNIMPORT {
			addpltsym(targ)
			r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
			r.Add += int64(targ.Plt)
		}

		return

	case 256 + ld.R_X86_64_GOTPCREL:
		if targ.Type != ld.SDYNIMPORT {
			// have symbol
			if r.Off >= 2 && s.P[r.Off-2] == 0x8b {
				// turn MOVQ of GOT entry into LEAQ of symbol itself
				s.P[r.Off-2] = 0x8d

				r.Type = ld.R_PCREL
				r.Add += 4
				return
			}
		}

		// fall back to using GOT and hope for the best (CMOV*)
		// TODO: just needs relocation, no need to put in .dynsym
		addgotsym(targ)

		r.Type = ld.R_PCREL
		r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0)
		r.Add += 4
		r.Add += int64(targ.Got)
		return

	case 256 + ld.R_X86_64_64:
		if targ.Type == ld.SDYNIMPORT {
			ld.Diag("unexpected R_X86_64_64 relocation for dynamic symbol %s", targ.Name)
		}
		r.Type = ld.R_ADDR
		return

	// Handle relocations found in Mach-O object files.
	case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 0,
		512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 0,
		512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 0:
		// TODO: What is the difference between all these?
		r.Type = ld.R_ADDR

		if targ.Type == ld.SDYNIMPORT {
			ld.Diag("unexpected reloc for dynamic symbol %s", targ.Name)
		}
		return

	case 512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 1:
		if targ.Type == ld.SDYNIMPORT {
			addpltsym(targ)
			r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
			r.Add = int64(targ.Plt)
			r.Type = ld.R_PCREL
			return
		}
		fallthrough

		// fall through
	case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED_1*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED_2*2 + 1,
		512 + ld.MACHO_X86_64_RELOC_SIGNED_4*2 + 1:
		r.Type = ld.R_PCREL

		if targ.Type == ld.SDYNIMPORT {
			ld.Diag("unexpected pc-relative reloc for dynamic symbol %s", targ.Name)
		}
		return

	case 512 + ld.MACHO_X86_64_RELOC_GOT_LOAD*2 + 1:
		if targ.Type != ld.SDYNIMPORT {
			// have symbol
			// turn MOVQ of GOT entry into LEAQ of symbol itself
			if r.Off < 2 || s.P[r.Off-2] != 0x8b {
				ld.Diag("unexpected GOT_LOAD reloc for non-dynamic symbol %s", targ.Name)
				return
			}

			s.P[r.Off-2] = 0x8d
			r.Type = ld.R_PCREL
			return
		}
		fallthrough

		// fall through
	case 512 + ld.MACHO_X86_64_RELOC_GOT*2 + 1:
		if targ.Type != ld.SDYNIMPORT {
			ld.Diag("unexpected GOT reloc for non-dynamic symbol %s", targ.Name)
		}
		addgotsym(targ)
		r.Type = ld.R_PCREL
		r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0)
		r.Add += int64(targ.Got)
		return
	}

	// Handle references to ELF symbols from our own object files.
	if targ.Type != ld.SDYNIMPORT {
		return
	}

	switch r.Type {
	case ld.R_CALL,
		ld.R_PCREL:
		if ld.HEADTYPE == ld.Hwindows {
			// nothing to do, the relocation will be laid out in pereloc1
			return
		} else {
			// for both ELF and Mach-O
			addpltsym(targ)
			r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
			r.Add = int64(targ.Plt)
			return
		}

	case ld.R_ADDR:
		if s.Type == ld.STEXT && ld.Iself {
			// The code is asking for the address of an external
			// function.  We provide it with the address of the
			// correspondent GOT symbol.
			addgotsym(targ)

			r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0)
			r.Add += int64(targ.Got)
			return
		}

		if s.Type != ld.SDATA {
			break
		}
		if ld.Iself {
			adddynsym(ld.Ctxt, targ)
			rela := ld.Linklookup(ld.Ctxt, ".rela", 0)
			ld.Addaddrplus(ld.Ctxt, rela, s, int64(r.Off))
			if r.Siz == 8 {
				ld.Adduint64(ld.Ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_X86_64_64))
			} else {
				ld.Adduint64(ld.Ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_X86_64_32))
			}
			ld.Adduint64(ld.Ctxt, rela, uint64(r.Add))
			r.Type = 256 // ignore during relocsym
			return
		}

		if ld.HEADTYPE == ld.Hdarwin && s.Size == int64(ld.Thearch.Ptrsize) && r.Off == 0 {
			// Mach-O relocations are a royal pain to lay out.
			// They use a compact stateful bytecode representation
			// that is too much bother to deal with.
			// Instead, interpret the C declaration
			//	void *_Cvar_stderr = &stderr;
			// as making _Cvar_stderr the name of a GOT entry
			// for stderr.  This is separate from the usual GOT entry,
			// just in case the C code assigns to the variable,
			// and of course it only works for single pointers,
			// but we only need to support cgo and that's all it needs.
			adddynsym(ld.Ctxt, targ)

			got := ld.Linklookup(ld.Ctxt, ".got", 0)
			s.Type = got.Type | ld.SSUB
			s.Outer = got
			s.Sub = got.Sub
			got.Sub = s
			s.Value = got.Size
			ld.Adduint64(ld.Ctxt, got, 0)
			ld.Adduint32(ld.Ctxt, ld.Linklookup(ld.Ctxt, ".linkedit.got", 0), uint32(targ.Dynid))
			r.Type = 256 // ignore during relocsym
			return
		}

		if ld.HEADTYPE == ld.Hwindows {
			// nothing to do, the relocation will be laid out in pereloc1
			return
		}
	}

	ld.Ctxt.Cursym = s
	ld.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type)
}
Beispiel #3
0
func adddynrel(s *ld.LSym, r *ld.Reloc) {
	targ := r.Sym
	ld.Ctxt.Cursym = s

	switch r.Type {
	default:
		if r.Type >= 256 {
			ld.Diag("unexpected relocation type %d", r.Type)
			return
		}

		// Handle relocations found in ELF object files.
	case 256 + ld.R_PPC64_REL24:
		r.Type = ld.R_CALLPOWER

		// This is a local call, so the caller isn't setting
		// up r12 and r2 is the same for the caller and
		// callee.  Hence, we need to go to the local entry
		// point.  (If we don't do this, the callee will try
		// to use r12 to compute r2.)
		r.Add += int64(r.Sym.Localentry) * 4

		if targ.Type == ld.SDYNIMPORT {
			// Should have been handled in elfsetupplt
			ld.Diag("unexpected R_PPC64_REL24 for dyn import")
		}

		return

	case 256 + ld.R_PPC64_ADDR64:
		r.Type = ld.R_ADDR
		if targ.Type == ld.SDYNIMPORT {
			// These happen in .toc sections
			adddynsym(ld.Ctxt, targ)

			rela := ld.Linklookup(ld.Ctxt, ".rela", 0)
			ld.Addaddrplus(ld.Ctxt, rela, s, int64(r.Off))
			ld.Adduint64(ld.Ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_PPC64_ADDR64))
			ld.Adduint64(ld.Ctxt, rela, uint64(r.Add))
			r.Type = 256 // ignore during relocsym
		}

		return

	case 256 + ld.R_PPC64_TOC16:
		r.Type = ld.R_POWER_TOC
		r.Variant = ld.RV_POWER_LO | ld.RV_CHECK_OVERFLOW
		return

	case 256 + ld.R_PPC64_TOC16_LO:
		r.Type = ld.R_POWER_TOC
		r.Variant = ld.RV_POWER_LO
		return

	case 256 + ld.R_PPC64_TOC16_HA:
		r.Type = ld.R_POWER_TOC
		r.Variant = ld.RV_POWER_HA | ld.RV_CHECK_OVERFLOW
		return

	case 256 + ld.R_PPC64_TOC16_HI:
		r.Type = ld.R_POWER_TOC
		r.Variant = ld.RV_POWER_HI | ld.RV_CHECK_OVERFLOW
		return

	case 256 + ld.R_PPC64_TOC16_DS:
		r.Type = ld.R_POWER_TOC
		r.Variant = ld.RV_POWER_DS | ld.RV_CHECK_OVERFLOW
		return

	case 256 + ld.R_PPC64_TOC16_LO_DS:
		r.Type = ld.R_POWER_TOC
		r.Variant = ld.RV_POWER_DS
		return

	case 256 + ld.R_PPC64_REL16_LO:
		r.Type = ld.R_PCREL
		r.Variant = ld.RV_POWER_LO
		r.Add += 2 // Compensate for relocation size of 2
		return

	case 256 + ld.R_PPC64_REL16_HI:
		r.Type = ld.R_PCREL
		r.Variant = ld.RV_POWER_HI | ld.RV_CHECK_OVERFLOW
		r.Add += 2
		return

	case 256 + ld.R_PPC64_REL16_HA:
		r.Type = ld.R_PCREL
		r.Variant = ld.RV_POWER_HA | ld.RV_CHECK_OVERFLOW
		r.Add += 2
		return
	}

	// Handle references to ELF symbols from our own object files.
	if targ.Type != ld.SDYNIMPORT {
		return
	}

	// TODO(austin): Translate our relocations to ELF

	ld.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type)
}
Beispiel #4
0
func adddynrel(s *ld.LSym, r *ld.Reloc) {
	targ := r.Sym
	ld.Ctxt.Cursym = s

	switch r.Type {
	default:
		if r.Type >= 256 {
			ld.Diag("unexpected relocation type %d", r.Type)
			return
		}

		// Handle relocations found in ELF object files.
	case 256 + ld.R_386_PC32:
		if targ.Type == ld.SDYNIMPORT {
			ld.Diag("unexpected R_386_PC32 relocation for dynamic symbol %s", targ.Name)
		}
		if targ.Type == 0 || targ.Type == ld.SXREF {
			ld.Diag("unknown symbol %s in pcrel", targ.Name)
		}
		r.Type = ld.R_PCREL
		r.Add += 4
		return

	case 256 + ld.R_386_PLT32:
		r.Type = ld.R_PCREL
		r.Add += 4
		if targ.Type == ld.SDYNIMPORT {
			addpltsym(ld.Ctxt, targ)
			r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
			r.Add += int64(targ.Plt)
		}

		return

	case 256 + ld.R_386_GOT32:
		if targ.Type != ld.SDYNIMPORT {
			// have symbol
			if r.Off >= 2 && s.P[r.Off-2] == 0x8b {
				// turn MOVL of GOT entry into LEAL of symbol address, relative to GOT.
				s.P[r.Off-2] = 0x8d

				r.Type = ld.R_GOTOFF
				return
			}

			if r.Off >= 2 && s.P[r.Off-2] == 0xff && s.P[r.Off-1] == 0xb3 {
				// turn PUSHL of GOT entry into PUSHL of symbol itself.
				// use unnecessary SS prefix to keep instruction same length.
				s.P[r.Off-2] = 0x36

				s.P[r.Off-1] = 0x68
				r.Type = ld.R_ADDR
				return
			}

			ld.Diag("unexpected GOT reloc for non-dynamic symbol %s", targ.Name)
			return
		}

		addgotsym(ld.Ctxt, targ)
		r.Type = ld.R_CONST // write r->add during relocsym
		r.Sym = nil
		r.Add += int64(targ.Got)
		return

	case 256 + ld.R_386_GOTOFF:
		r.Type = ld.R_GOTOFF
		return

	case 256 + ld.R_386_GOTPC:
		r.Type = ld.R_PCREL
		r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0)
		r.Add += 4
		return

	case 256 + ld.R_386_32:
		if targ.Type == ld.SDYNIMPORT {
			ld.Diag("unexpected R_386_32 relocation for dynamic symbol %s", targ.Name)
		}
		r.Type = ld.R_ADDR
		return

	case 512 + ld.MACHO_GENERIC_RELOC_VANILLA*2 + 0:
		r.Type = ld.R_ADDR
		if targ.Type == ld.SDYNIMPORT {
			ld.Diag("unexpected reloc for dynamic symbol %s", targ.Name)
		}
		return

	case 512 + ld.MACHO_GENERIC_RELOC_VANILLA*2 + 1:
		if targ.Type == ld.SDYNIMPORT {
			addpltsym(ld.Ctxt, targ)
			r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
			r.Add = int64(targ.Plt)
			r.Type = ld.R_PCREL
			return
		}

		r.Type = ld.R_PCREL
		return

	case 512 + ld.MACHO_FAKE_GOTPCREL:
		if targ.Type != ld.SDYNIMPORT {
			// have symbol
			// turn MOVL of GOT entry into LEAL of symbol itself
			if r.Off < 2 || s.P[r.Off-2] != 0x8b {
				ld.Diag("unexpected GOT reloc for non-dynamic symbol %s", targ.Name)
				return
			}

			s.P[r.Off-2] = 0x8d
			r.Type = ld.R_PCREL
			return
		}

		addgotsym(ld.Ctxt, targ)
		r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0)
		r.Add += int64(targ.Got)
		r.Type = ld.R_PCREL
		return
	}

	// Handle references to ELF symbols from our own object files.
	if targ.Type != ld.SDYNIMPORT {
		return
	}

	switch r.Type {
	case ld.R_CALL,
		ld.R_PCREL:
		addpltsym(ld.Ctxt, targ)
		r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
		r.Add = int64(targ.Plt)
		return

	case ld.R_ADDR:
		if s.Type != ld.SDATA {
			break
		}
		if ld.Iself {
			adddynsym(ld.Ctxt, targ)
			rel := ld.Linklookup(ld.Ctxt, ".rel", 0)
			ld.Addaddrplus(ld.Ctxt, rel, s, int64(r.Off))
			ld.Adduint32(ld.Ctxt, rel, ld.ELF32_R_INFO(uint32(targ.Dynid), ld.R_386_32))
			r.Type = ld.R_CONST // write r->add during relocsym
			r.Sym = nil
			return
		}

		if ld.HEADTYPE == ld.Hdarwin && s.Size == PtrSize && r.Off == 0 {
			// Mach-O relocations are a royal pain to lay out.
			// They use a compact stateful bytecode representation
			// that is too much bother to deal with.
			// Instead, interpret the C declaration
			//	void *_Cvar_stderr = &stderr;
			// as making _Cvar_stderr the name of a GOT entry
			// for stderr.  This is separate from the usual GOT entry,
			// just in case the C code assigns to the variable,
			// and of course it only works for single pointers,
			// but we only need to support cgo and that's all it needs.
			adddynsym(ld.Ctxt, targ)

			got := ld.Linklookup(ld.Ctxt, ".got", 0)
			s.Type = got.Type | ld.SSUB
			s.Outer = got
			s.Sub = got.Sub
			got.Sub = s
			s.Value = got.Size
			ld.Adduint32(ld.Ctxt, got, 0)
			ld.Adduint32(ld.Ctxt, ld.Linklookup(ld.Ctxt, ".linkedit.got", 0), uint32(targ.Dynid))
			r.Type = 256 // ignore during relocsym
			return
		}

		if ld.HEADTYPE == ld.Hwindows && s.Size == PtrSize {
			// nothing to do, the relocation will be laid out in pereloc1
			return
		}
	}

	ld.Ctxt.Cursym = s
	ld.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type)
}
Beispiel #5
0
func archreloc(r *ld.Reloc, s *ld.LSym, val *int64) int {
	if ld.Linkmode == ld.LinkExternal {
		switch r.Type {
		default:
			return -1

		case obj.R_ADDRARM64:
			r.Done = 0

			// set up addend for eventual relocation via outer symbol.
			rs := r.Sym
			r.Xadd = r.Add
			for rs.Outer != nil {
				r.Xadd += ld.Symaddr(rs) - ld.Symaddr(rs.Outer)
				rs = rs.Outer
			}

			if rs.Type != obj.SHOSTOBJ && rs.Sect == nil {
				ld.Diag("missing section for %s", rs.Name)
			}
			r.Xsym = rs

			// the first instruction is always at the lower address, this is endian neutral;
			// but note that o0 and o1 should still use the target endian.
			o0 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off : r.Off+4])
			o1 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off+4 : r.Off+8])

			// Note: ld64 currently has a bug that any non-zero addend for BR26 relocation
			// will make the linking fail because it thinks the code is not PIC even though
			// the BR26 relocation should be fully resolved at link time.
			// That is the reason why the next if block is disabled. When the bug in ld64
			// is fixed, we can enable this block and also enable duff's device in cmd/7g.
			if false && ld.HEADTYPE == obj.Hdarwin {
				// Mach-O wants the addend to be encoded in the instruction
				// Note that although Mach-O supports ARM64_RELOC_ADDEND, it
				// can only encode 24-bit of signed addend, but the instructions
				// supports 33-bit of signed addend, so we always encode the
				// addend in place.
				o0 |= (uint32((r.Xadd>>12)&3) << 29) | (uint32((r.Xadd>>12>>2)&0x7ffff) << 5)
				o1 |= uint32(r.Xadd&0xfff) << 10
				r.Xadd = 0
			}

			// when laid out, the instruction order must always be o1, o2.
			if ld.Ctxt.Arch.ByteOrder == binary.BigEndian {
				*val = int64(o0)<<32 | int64(o1)
			} else {
				*val = int64(o1)<<32 | int64(o0)
			}

			return 0

		case obj.R_CALLARM64:
			r.Done = 0
			r.Xsym = r.Sym
			*val = int64(0xfc000000 & uint32(r.Add))
			r.Xadd = int64((uint32(r.Add) &^ 0xfc000000) * 4)
			r.Add = 0
			return 0
		}
	}

	switch r.Type {
	case obj.R_CONST:
		*val = r.Add
		return 0

	case obj.R_GOTOFF:
		*val = ld.Symaddr(r.Sym) + r.Add - ld.Symaddr(ld.Linklookup(ld.Ctxt, ".got", 0))
		return 0

	case obj.R_ADDRARM64:
		t := ld.Symaddr(r.Sym) + r.Add - ((s.Value + int64(r.Off)) &^ 0xfff)
		if t >= 1<<32 || t < -1<<32 {
			ld.Diag("program too large, address relocation distance = %d", t)
		}

		// the first instruction is always at the lower address, this is endian neutral;
		// but note that o0 and o1 should still use the target endian.
		o0 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off : r.Off+4])
		o1 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off+4 : r.Off+8])

		o0 |= (uint32((t>>12)&3) << 29) | (uint32((t>>12>>2)&0x7ffff) << 5)
		o1 |= uint32(t&0xfff) << 10

		// when laid out, the instruction order must always be o1, o2.
		if ld.Ctxt.Arch.ByteOrder == binary.BigEndian {
			*val = int64(o0)<<32 | int64(o1)
		} else {
			*val = int64(o1)<<32 | int64(o0)
		}
		return 0

	case obj.R_CALLARM64:
		*val = int64((0xfc000000 & uint32(r.Add)) | uint32((ld.Symaddr(r.Sym)+r.Add*4-(s.Value+int64(r.Off)))/4))
		return 0
	}

	return -1
}
Beispiel #6
0
func archreloc(r *ld.Reloc, s *ld.LSym, val *int64) int {
	if ld.Linkmode == ld.LinkExternal {
		switch r.Type {
		default:
			return -1

		case ld.R_ADDRARM64:
			r.Done = 0

			// the first instruction is always at the lower address, this is endian neutral;
			// but note that o0 and o1 should still use the target endian.
			o0 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off : r.Off+4])
			o1 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off+4 : r.Off+8])

			// when laid out, the instruction order must always be o1, o2.
			if ld.Ctxt.Arch.ByteOrder == binary.BigEndian {
				*val = int64(o0)<<32 | int64(o1)
			} else {
				*val = int64(o1)<<32 | int64(o0)
			}

			// set up addend for eventual relocation via outer symbol.
			rs := r.Sym
			r.Xadd = r.Add
			for rs.Outer != nil {
				r.Xadd += ld.Symaddr(rs) - ld.Symaddr(rs.Outer)
				rs = rs.Outer
			}

			if rs.Type != ld.SHOSTOBJ && rs.Sect == nil {
				ld.Diag("missing section for %s", rs.Name)
			}
			r.Xsym = rs

			return 0

		case ld.R_CALLARM64:
			r.Done = 0
			r.Xsym = r.Sym
			*val = int64(0xfc000000 & uint32(r.Add))
			r.Xadd = int64((uint32(r.Add) &^ 0xfc000000) * 4)
			r.Add = 0
			return 0
		}
	}

	switch r.Type {
	case ld.R_CONST:
		*val = r.Add
		return 0

	case ld.R_GOTOFF:
		*val = ld.Symaddr(r.Sym) + r.Add - ld.Symaddr(ld.Linklookup(ld.Ctxt, ".got", 0))
		return 0

	case ld.R_ADDRARM64:
		t := ld.Symaddr(r.Sym) + r.Add - ((s.Value + int64(r.Off)) &^ 0xfff)
		if t >= 1<<32 || t < -1<<32 {
			ld.Diag("program too large, address relocation distance = %d", t)
		}

		// the first instruction is always at the lower address, this is endian neutral;
		// but note that o0 and o1 should still use the target endian.
		o0 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off : r.Off+4])
		o1 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off+4 : r.Off+8])

		o0 |= (uint32((t>>12)&3) << 29) | (uint32((t>>12>>2)&0x7ffff) << 5)
		o1 |= uint32(t&0xfff) << 10

		// when laid out, the instruction order must always be o1, o2.
		if ld.Ctxt.Arch.ByteOrder == binary.BigEndian {
			*val = int64(o0)<<32 | int64(o1)
		} else {
			*val = int64(o1)<<32 | int64(o0)
		}
		return 0

	case ld.R_CALLARM64:
		*val = int64((0xfc000000 & uint32(r.Add)) | uint32((ld.Symaddr(r.Sym)+r.Add*4-(s.Value+int64(r.Off)))/4))
		return 0
	}

	return -1
}