func adddynrel(s *ld.LSym, r *ld.Reloc) { targ := r.Sym ld.Ctxt.Cursym = s switch r.Type { default: if r.Type >= 256 { ld.Diag("unexpected relocation type %d", r.Type) return } // Handle relocations found in ELF object files. case 256 + ld.R_ARM_PLT32: r.Type = ld.R_CALLARM if targ.Type == ld.SDYNIMPORT { addpltsym(ld.Ctxt, targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add = int64(braddoff(int32(r.Add), targ.Plt/4)) } return case 256 + ld.R_ARM_THM_PC22: // R_ARM_THM_CALL ld.Diag("R_ARM_THM_CALL, are you using -marm?") ld.Errorexit() return case 256 + ld.R_ARM_GOT32: // R_ARM_GOT_BREL if targ.Type != ld.SDYNIMPORT { addgotsyminternal(ld.Ctxt, targ) } else { addgotsym(ld.Ctxt, targ) } r.Type = ld.R_CONST // write r->add during relocsym r.Sym = nil r.Add += int64(targ.Got) return case 256 + ld.R_ARM_GOT_PREL: // GOT(nil) + A - nil if targ.Type != ld.SDYNIMPORT { addgotsyminternal(ld.Ctxt, targ) } else { addgotsym(ld.Ctxt, targ) } r.Type = ld.R_PCREL r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0) r.Add += int64(targ.Got) + 4 return case 256 + ld.R_ARM_GOTOFF: // R_ARM_GOTOFF32 r.Type = ld.R_GOTOFF return case 256 + ld.R_ARM_GOTPC: // R_ARM_BASE_PREL r.Type = ld.R_PCREL r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0) r.Add += 4 return case 256 + ld.R_ARM_CALL: r.Type = ld.R_CALLARM if targ.Type == ld.SDYNIMPORT { addpltsym(ld.Ctxt, targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add = int64(braddoff(int32(r.Add), targ.Plt/4)) } return case 256 + ld.R_ARM_REL32: // R_ARM_REL32 r.Type = ld.R_PCREL r.Add += 4 return case 256 + ld.R_ARM_ABS32: if targ.Type == ld.SDYNIMPORT { ld.Diag("unexpected R_ARM_ABS32 relocation for dynamic symbol %s", targ.Name) } r.Type = ld.R_ADDR return // we can just ignore this, because we are targeting ARM V5+ anyway case 256 + ld.R_ARM_V4BX: if r.Sym != nil { // R_ARM_V4BX is ABS relocation, so this symbol is a dummy symbol, ignore it r.Sym.Type = 0 } r.Sym = nil return case 256 + ld.R_ARM_PC24, 256 + ld.R_ARM_JUMP24: r.Type = ld.R_CALLARM if targ.Type == ld.SDYNIMPORT { addpltsym(ld.Ctxt, targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add = int64(braddoff(int32(r.Add), targ.Plt/4)) } return } // Handle references to ELF symbols from our own object files. if targ.Type != ld.SDYNIMPORT { return } switch r.Type { case ld.R_CALLARM: addpltsym(ld.Ctxt, targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add = int64(targ.Plt) return case ld.R_ADDR: if s.Type != ld.SDATA { break } if ld.Iself { adddynsym(ld.Ctxt, targ) rel := ld.Linklookup(ld.Ctxt, ".rel", 0) ld.Addaddrplus(ld.Ctxt, rel, s, int64(r.Off)) ld.Adduint32(ld.Ctxt, rel, ld.ELF32_R_INFO(uint32(targ.Dynid), ld.R_ARM_GLOB_DAT)) // we need a nil + A dynmic reloc r.Type = ld.R_CONST // write r->add during relocsym r.Sym = nil return } } ld.Ctxt.Cursym = s ld.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type) }
func adddynrel(s *ld.LSym, r *ld.Reloc) { targ := r.Sym ld.Ctxt.Cursym = s switch r.Type { default: if r.Type >= 256 { ld.Diag("unexpected relocation type %d", r.Type) return } // Handle relocations found in ELF object files. case 256 + ld.R_X86_64_PC32: if targ.Type == ld.SDYNIMPORT { ld.Diag("unexpected R_X86_64_PC32 relocation for dynamic symbol %s", targ.Name) } if targ.Type == 0 || targ.Type == ld.SXREF { ld.Diag("unknown symbol %s in pcrel", targ.Name) } r.Type = ld.R_PCREL r.Add += 4 return case 256 + ld.R_X86_64_PLT32: r.Type = ld.R_PCREL r.Add += 4 if targ.Type == ld.SDYNIMPORT { addpltsym(targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add += int64(targ.Plt) } return case 256 + ld.R_X86_64_GOTPCREL: if targ.Type != ld.SDYNIMPORT { // have symbol if r.Off >= 2 && s.P[r.Off-2] == 0x8b { // turn MOVQ of GOT entry into LEAQ of symbol itself s.P[r.Off-2] = 0x8d r.Type = ld.R_PCREL r.Add += 4 return } } // fall back to using GOT and hope for the best (CMOV*) // TODO: just needs relocation, no need to put in .dynsym addgotsym(targ) r.Type = ld.R_PCREL r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0) r.Add += 4 r.Add += int64(targ.Got) return case 256 + ld.R_X86_64_64: if targ.Type == ld.SDYNIMPORT { ld.Diag("unexpected R_X86_64_64 relocation for dynamic symbol %s", targ.Name) } r.Type = ld.R_ADDR return // Handle relocations found in Mach-O object files. case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 0, 512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 0, 512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 0: // TODO: What is the difference between all these? r.Type = ld.R_ADDR if targ.Type == ld.SDYNIMPORT { ld.Diag("unexpected reloc for dynamic symbol %s", targ.Name) } return case 512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 1: if targ.Type == ld.SDYNIMPORT { addpltsym(targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add = int64(targ.Plt) r.Type = ld.R_PCREL return } fallthrough // fall through case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 1, 512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 1, 512 + ld.MACHO_X86_64_RELOC_SIGNED_1*2 + 1, 512 + ld.MACHO_X86_64_RELOC_SIGNED_2*2 + 1, 512 + ld.MACHO_X86_64_RELOC_SIGNED_4*2 + 1: r.Type = ld.R_PCREL if targ.Type == ld.SDYNIMPORT { ld.Diag("unexpected pc-relative reloc for dynamic symbol %s", targ.Name) } return case 512 + ld.MACHO_X86_64_RELOC_GOT_LOAD*2 + 1: if targ.Type != ld.SDYNIMPORT { // have symbol // turn MOVQ of GOT entry into LEAQ of symbol itself if r.Off < 2 || s.P[r.Off-2] != 0x8b { ld.Diag("unexpected GOT_LOAD reloc for non-dynamic symbol %s", targ.Name) return } s.P[r.Off-2] = 0x8d r.Type = ld.R_PCREL return } fallthrough // fall through case 512 + ld.MACHO_X86_64_RELOC_GOT*2 + 1: if targ.Type != ld.SDYNIMPORT { ld.Diag("unexpected GOT reloc for non-dynamic symbol %s", targ.Name) } addgotsym(targ) r.Type = ld.R_PCREL r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0) r.Add += int64(targ.Got) return } // Handle references to ELF symbols from our own object files. if targ.Type != ld.SDYNIMPORT { return } switch r.Type { case ld.R_CALL, ld.R_PCREL: if ld.HEADTYPE == ld.Hwindows { // nothing to do, the relocation will be laid out in pereloc1 return } else { // for both ELF and Mach-O addpltsym(targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add = int64(targ.Plt) return } case ld.R_ADDR: if s.Type == ld.STEXT && ld.Iself { // The code is asking for the address of an external // function. We provide it with the address of the // correspondent GOT symbol. addgotsym(targ) r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0) r.Add += int64(targ.Got) return } if s.Type != ld.SDATA { break } if ld.Iself { adddynsym(ld.Ctxt, targ) rela := ld.Linklookup(ld.Ctxt, ".rela", 0) ld.Addaddrplus(ld.Ctxt, rela, s, int64(r.Off)) if r.Siz == 8 { ld.Adduint64(ld.Ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_X86_64_64)) } else { ld.Adduint64(ld.Ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_X86_64_32)) } ld.Adduint64(ld.Ctxt, rela, uint64(r.Add)) r.Type = 256 // ignore during relocsym return } if ld.HEADTYPE == ld.Hdarwin && s.Size == int64(ld.Thearch.Ptrsize) && r.Off == 0 { // Mach-O relocations are a royal pain to lay out. // They use a compact stateful bytecode representation // that is too much bother to deal with. // Instead, interpret the C declaration // void *_Cvar_stderr = &stderr; // as making _Cvar_stderr the name of a GOT entry // for stderr. This is separate from the usual GOT entry, // just in case the C code assigns to the variable, // and of course it only works for single pointers, // but we only need to support cgo and that's all it needs. adddynsym(ld.Ctxt, targ) got := ld.Linklookup(ld.Ctxt, ".got", 0) s.Type = got.Type | ld.SSUB s.Outer = got s.Sub = got.Sub got.Sub = s s.Value = got.Size ld.Adduint64(ld.Ctxt, got, 0) ld.Adduint32(ld.Ctxt, ld.Linklookup(ld.Ctxt, ".linkedit.got", 0), uint32(targ.Dynid)) r.Type = 256 // ignore during relocsym return } if ld.HEADTYPE == ld.Hwindows { // nothing to do, the relocation will be laid out in pereloc1 return } } ld.Ctxt.Cursym = s ld.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type) }
func adddynrel(s *ld.LSym, r *ld.Reloc) { targ := r.Sym ld.Ctxt.Cursym = s switch r.Type { default: if r.Type >= 256 { ld.Diag("unexpected relocation type %d", r.Type) return } // Handle relocations found in ELF object files. case 256 + ld.R_PPC64_REL24: r.Type = ld.R_CALLPOWER // This is a local call, so the caller isn't setting // up r12 and r2 is the same for the caller and // callee. Hence, we need to go to the local entry // point. (If we don't do this, the callee will try // to use r12 to compute r2.) r.Add += int64(r.Sym.Localentry) * 4 if targ.Type == ld.SDYNIMPORT { // Should have been handled in elfsetupplt ld.Diag("unexpected R_PPC64_REL24 for dyn import") } return case 256 + ld.R_PPC64_ADDR64: r.Type = ld.R_ADDR if targ.Type == ld.SDYNIMPORT { // These happen in .toc sections adddynsym(ld.Ctxt, targ) rela := ld.Linklookup(ld.Ctxt, ".rela", 0) ld.Addaddrplus(ld.Ctxt, rela, s, int64(r.Off)) ld.Adduint64(ld.Ctxt, rela, ld.ELF64_R_INFO(uint32(targ.Dynid), ld.R_PPC64_ADDR64)) ld.Adduint64(ld.Ctxt, rela, uint64(r.Add)) r.Type = 256 // ignore during relocsym } return case 256 + ld.R_PPC64_TOC16: r.Type = ld.R_POWER_TOC r.Variant = ld.RV_POWER_LO | ld.RV_CHECK_OVERFLOW return case 256 + ld.R_PPC64_TOC16_LO: r.Type = ld.R_POWER_TOC r.Variant = ld.RV_POWER_LO return case 256 + ld.R_PPC64_TOC16_HA: r.Type = ld.R_POWER_TOC r.Variant = ld.RV_POWER_HA | ld.RV_CHECK_OVERFLOW return case 256 + ld.R_PPC64_TOC16_HI: r.Type = ld.R_POWER_TOC r.Variant = ld.RV_POWER_HI | ld.RV_CHECK_OVERFLOW return case 256 + ld.R_PPC64_TOC16_DS: r.Type = ld.R_POWER_TOC r.Variant = ld.RV_POWER_DS | ld.RV_CHECK_OVERFLOW return case 256 + ld.R_PPC64_TOC16_LO_DS: r.Type = ld.R_POWER_TOC r.Variant = ld.RV_POWER_DS return case 256 + ld.R_PPC64_REL16_LO: r.Type = ld.R_PCREL r.Variant = ld.RV_POWER_LO r.Add += 2 // Compensate for relocation size of 2 return case 256 + ld.R_PPC64_REL16_HI: r.Type = ld.R_PCREL r.Variant = ld.RV_POWER_HI | ld.RV_CHECK_OVERFLOW r.Add += 2 return case 256 + ld.R_PPC64_REL16_HA: r.Type = ld.R_PCREL r.Variant = ld.RV_POWER_HA | ld.RV_CHECK_OVERFLOW r.Add += 2 return } // Handle references to ELF symbols from our own object files. if targ.Type != ld.SDYNIMPORT { return } // TODO(austin): Translate our relocations to ELF ld.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type) }
func adddynrel(s *ld.LSym, r *ld.Reloc) { targ := r.Sym ld.Ctxt.Cursym = s switch r.Type { default: if r.Type >= 256 { ld.Diag("unexpected relocation type %d", r.Type) return } // Handle relocations found in ELF object files. case 256 + ld.R_386_PC32: if targ.Type == ld.SDYNIMPORT { ld.Diag("unexpected R_386_PC32 relocation for dynamic symbol %s", targ.Name) } if targ.Type == 0 || targ.Type == ld.SXREF { ld.Diag("unknown symbol %s in pcrel", targ.Name) } r.Type = ld.R_PCREL r.Add += 4 return case 256 + ld.R_386_PLT32: r.Type = ld.R_PCREL r.Add += 4 if targ.Type == ld.SDYNIMPORT { addpltsym(ld.Ctxt, targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add += int64(targ.Plt) } return case 256 + ld.R_386_GOT32: if targ.Type != ld.SDYNIMPORT { // have symbol if r.Off >= 2 && s.P[r.Off-2] == 0x8b { // turn MOVL of GOT entry into LEAL of symbol address, relative to GOT. s.P[r.Off-2] = 0x8d r.Type = ld.R_GOTOFF return } if r.Off >= 2 && s.P[r.Off-2] == 0xff && s.P[r.Off-1] == 0xb3 { // turn PUSHL of GOT entry into PUSHL of symbol itself. // use unnecessary SS prefix to keep instruction same length. s.P[r.Off-2] = 0x36 s.P[r.Off-1] = 0x68 r.Type = ld.R_ADDR return } ld.Diag("unexpected GOT reloc for non-dynamic symbol %s", targ.Name) return } addgotsym(ld.Ctxt, targ) r.Type = ld.R_CONST // write r->add during relocsym r.Sym = nil r.Add += int64(targ.Got) return case 256 + ld.R_386_GOTOFF: r.Type = ld.R_GOTOFF return case 256 + ld.R_386_GOTPC: r.Type = ld.R_PCREL r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0) r.Add += 4 return case 256 + ld.R_386_32: if targ.Type == ld.SDYNIMPORT { ld.Diag("unexpected R_386_32 relocation for dynamic symbol %s", targ.Name) } r.Type = ld.R_ADDR return case 512 + ld.MACHO_GENERIC_RELOC_VANILLA*2 + 0: r.Type = ld.R_ADDR if targ.Type == ld.SDYNIMPORT { ld.Diag("unexpected reloc for dynamic symbol %s", targ.Name) } return case 512 + ld.MACHO_GENERIC_RELOC_VANILLA*2 + 1: if targ.Type == ld.SDYNIMPORT { addpltsym(ld.Ctxt, targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add = int64(targ.Plt) r.Type = ld.R_PCREL return } r.Type = ld.R_PCREL return case 512 + ld.MACHO_FAKE_GOTPCREL: if targ.Type != ld.SDYNIMPORT { // have symbol // turn MOVL of GOT entry into LEAL of symbol itself if r.Off < 2 || s.P[r.Off-2] != 0x8b { ld.Diag("unexpected GOT reloc for non-dynamic symbol %s", targ.Name) return } s.P[r.Off-2] = 0x8d r.Type = ld.R_PCREL return } addgotsym(ld.Ctxt, targ) r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0) r.Add += int64(targ.Got) r.Type = ld.R_PCREL return } // Handle references to ELF symbols from our own object files. if targ.Type != ld.SDYNIMPORT { return } switch r.Type { case ld.R_CALL, ld.R_PCREL: addpltsym(ld.Ctxt, targ) r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0) r.Add = int64(targ.Plt) return case ld.R_ADDR: if s.Type != ld.SDATA { break } if ld.Iself { adddynsym(ld.Ctxt, targ) rel := ld.Linklookup(ld.Ctxt, ".rel", 0) ld.Addaddrplus(ld.Ctxt, rel, s, int64(r.Off)) ld.Adduint32(ld.Ctxt, rel, ld.ELF32_R_INFO(uint32(targ.Dynid), ld.R_386_32)) r.Type = ld.R_CONST // write r->add during relocsym r.Sym = nil return } if ld.HEADTYPE == ld.Hdarwin && s.Size == PtrSize && r.Off == 0 { // Mach-O relocations are a royal pain to lay out. // They use a compact stateful bytecode representation // that is too much bother to deal with. // Instead, interpret the C declaration // void *_Cvar_stderr = &stderr; // as making _Cvar_stderr the name of a GOT entry // for stderr. This is separate from the usual GOT entry, // just in case the C code assigns to the variable, // and of course it only works for single pointers, // but we only need to support cgo and that's all it needs. adddynsym(ld.Ctxt, targ) got := ld.Linklookup(ld.Ctxt, ".got", 0) s.Type = got.Type | ld.SSUB s.Outer = got s.Sub = got.Sub got.Sub = s s.Value = got.Size ld.Adduint32(ld.Ctxt, got, 0) ld.Adduint32(ld.Ctxt, ld.Linklookup(ld.Ctxt, ".linkedit.got", 0), uint32(targ.Dynid)) r.Type = 256 // ignore during relocsym return } if ld.HEADTYPE == ld.Hwindows && s.Size == PtrSize { // nothing to do, the relocation will be laid out in pereloc1 return } } ld.Ctxt.Cursym = s ld.Diag("unsupported relocation for dynamic symbol %s (type=%d stype=%d)", targ.Name, r.Type, targ.Type) }
func archreloc(r *ld.Reloc, s *ld.LSym, val *int64) int { if ld.Linkmode == ld.LinkExternal { switch r.Type { default: return -1 case obj.R_ADDRARM64: r.Done = 0 // set up addend for eventual relocation via outer symbol. rs := r.Sym r.Xadd = r.Add for rs.Outer != nil { r.Xadd += ld.Symaddr(rs) - ld.Symaddr(rs.Outer) rs = rs.Outer } if rs.Type != obj.SHOSTOBJ && rs.Sect == nil { ld.Diag("missing section for %s", rs.Name) } r.Xsym = rs // the first instruction is always at the lower address, this is endian neutral; // but note that o0 and o1 should still use the target endian. o0 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off : r.Off+4]) o1 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off+4 : r.Off+8]) // Note: ld64 currently has a bug that any non-zero addend for BR26 relocation // will make the linking fail because it thinks the code is not PIC even though // the BR26 relocation should be fully resolved at link time. // That is the reason why the next if block is disabled. When the bug in ld64 // is fixed, we can enable this block and also enable duff's device in cmd/7g. if false && ld.HEADTYPE == obj.Hdarwin { // Mach-O wants the addend to be encoded in the instruction // Note that although Mach-O supports ARM64_RELOC_ADDEND, it // can only encode 24-bit of signed addend, but the instructions // supports 33-bit of signed addend, so we always encode the // addend in place. o0 |= (uint32((r.Xadd>>12)&3) << 29) | (uint32((r.Xadd>>12>>2)&0x7ffff) << 5) o1 |= uint32(r.Xadd&0xfff) << 10 r.Xadd = 0 } // when laid out, the instruction order must always be o1, o2. if ld.Ctxt.Arch.ByteOrder == binary.BigEndian { *val = int64(o0)<<32 | int64(o1) } else { *val = int64(o1)<<32 | int64(o0) } return 0 case obj.R_CALLARM64: r.Done = 0 r.Xsym = r.Sym *val = int64(0xfc000000 & uint32(r.Add)) r.Xadd = int64((uint32(r.Add) &^ 0xfc000000) * 4) r.Add = 0 return 0 } } switch r.Type { case obj.R_CONST: *val = r.Add return 0 case obj.R_GOTOFF: *val = ld.Symaddr(r.Sym) + r.Add - ld.Symaddr(ld.Linklookup(ld.Ctxt, ".got", 0)) return 0 case obj.R_ADDRARM64: t := ld.Symaddr(r.Sym) + r.Add - ((s.Value + int64(r.Off)) &^ 0xfff) if t >= 1<<32 || t < -1<<32 { ld.Diag("program too large, address relocation distance = %d", t) } // the first instruction is always at the lower address, this is endian neutral; // but note that o0 and o1 should still use the target endian. o0 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off : r.Off+4]) o1 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off+4 : r.Off+8]) o0 |= (uint32((t>>12)&3) << 29) | (uint32((t>>12>>2)&0x7ffff) << 5) o1 |= uint32(t&0xfff) << 10 // when laid out, the instruction order must always be o1, o2. if ld.Ctxt.Arch.ByteOrder == binary.BigEndian { *val = int64(o0)<<32 | int64(o1) } else { *val = int64(o1)<<32 | int64(o0) } return 0 case obj.R_CALLARM64: *val = int64((0xfc000000 & uint32(r.Add)) | uint32((ld.Symaddr(r.Sym)+r.Add*4-(s.Value+int64(r.Off)))/4)) return 0 } return -1 }
func archreloc(r *ld.Reloc, s *ld.LSym, val *int64) int { if ld.Linkmode == ld.LinkExternal { switch r.Type { default: return -1 case ld.R_ADDRARM64: r.Done = 0 // the first instruction is always at the lower address, this is endian neutral; // but note that o0 and o1 should still use the target endian. o0 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off : r.Off+4]) o1 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off+4 : r.Off+8]) // when laid out, the instruction order must always be o1, o2. if ld.Ctxt.Arch.ByteOrder == binary.BigEndian { *val = int64(o0)<<32 | int64(o1) } else { *val = int64(o1)<<32 | int64(o0) } // set up addend for eventual relocation via outer symbol. rs := r.Sym r.Xadd = r.Add for rs.Outer != nil { r.Xadd += ld.Symaddr(rs) - ld.Symaddr(rs.Outer) rs = rs.Outer } if rs.Type != ld.SHOSTOBJ && rs.Sect == nil { ld.Diag("missing section for %s", rs.Name) } r.Xsym = rs return 0 case ld.R_CALLARM64: r.Done = 0 r.Xsym = r.Sym *val = int64(0xfc000000 & uint32(r.Add)) r.Xadd = int64((uint32(r.Add) &^ 0xfc000000) * 4) r.Add = 0 return 0 } } switch r.Type { case ld.R_CONST: *val = r.Add return 0 case ld.R_GOTOFF: *val = ld.Symaddr(r.Sym) + r.Add - ld.Symaddr(ld.Linklookup(ld.Ctxt, ".got", 0)) return 0 case ld.R_ADDRARM64: t := ld.Symaddr(r.Sym) + r.Add - ((s.Value + int64(r.Off)) &^ 0xfff) if t >= 1<<32 || t < -1<<32 { ld.Diag("program too large, address relocation distance = %d", t) } // the first instruction is always at the lower address, this is endian neutral; // but note that o0 and o1 should still use the target endian. o0 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off : r.Off+4]) o1 := ld.Thelinkarch.ByteOrder.Uint32(s.P[r.Off+4 : r.Off+8]) o0 |= (uint32((t>>12)&3) << 29) | (uint32((t>>12>>2)&0x7ffff) << 5) o1 |= uint32(t&0xfff) << 10 // when laid out, the instruction order must always be o1, o2. if ld.Ctxt.Arch.ByteOrder == binary.BigEndian { *val = int64(o0)<<32 | int64(o1) } else { *val = int64(o1)<<32 | int64(o0) } return 0 case ld.R_CALLARM64: *val = int64((0xfc000000 & uint32(r.Add)) | uint32((ld.Symaddr(r.Sym)+r.Add*4-(s.Value+int64(r.Off)))/4)) return 0 } return -1 }